Serving Del Norte County & the South Oregon Coast since 2009 Office: 707-465-0980  ·  Mon–Fri 7:30am–5:30pm
Home / Services

Ventilation services for the far north coast

Design, fabrication, installation, testing and maintenance — handled by one crew, so nothing falls between trades.

01 — Ventilation design & installation

Systems sized for the building, not the catalogue

Every project starts with a load calculation: occupancy, equipment heat, exhaust requirements, envelope tightness and outdoor design conditions for Crescent City specifically. Only then do we pick hardware.

We install supply and exhaust systems, make-up air units, rooftop packages, in-line and cabinet fans, and full ducted distribution. Residential retrofits in 1950s coastal cottages sit alongside 12,000 sq ft commercial fit-outs on the same schedule board.

  • ASHRAE 62.1 and 62.2 ventilation rate compliance
  • California Title 24 documentation prepared for your permit set
  • Equipment from Greenheck, Panasonic, Fantech, Broan and RenewAire
  • Coordination with your electrician and general contractor built into our schedule
Duct installation in progress
Technician taking an airflow reading at a ventilation grille
02 — Sheet metal fabrication

Built here, on Fairway Drive

Our shop runs a brake, shear, plasma table and spiral machine. That means odd transitions, tight-clearance plenums and one-off replacement sections get made the same week instead of waiting on a Sacramento supplier.

Standard stock is G90 galvanised; we run 304 stainless for kitchen and marine-exposed work, and aluminium where weight matters. All seams sealed to SMACNA leakage class, all joints labelled to the shop drawing so the install crew isn't guessing on a roof in the rain.

  • Rectangular, round and spiral duct to SMACNA standards
  • Custom hoods, curbs, transitions, boots and access doors
  • Stainless welded kitchen exhaust duct with liquid-tight seams
  • Shop drawings supplied for your records and inspector
03 — Indoor air quality

Dry air, in a place that isn't

Most air-quality calls we get here start with the same sentence: "there's black spotting in the corner of the bathroom." Nine times out of ten it isn't a cleaning problem — it's an air change problem plus a cold surface.

We measure relative humidity and surface temperatures, find where moisture is being generated and where it stalls, then fix the ventilation path. Heat and energy recovery ventilators let us bring in continuous fresh air without throwing away the heat you paid for.

  • HRV / ERV supply and installation with balanced commissioning
  • Filtration upgrades to MERV 11–16 where the equipment can carry it
  • Crawlspace and attic ventilation assessments
  • CO, CO₂ and humidity monitoring with logged data

What a healthy building looks like on paper

MeasureTarget
Indoor relative humidity40 – 55%
CO₂ (occupied space)under 1,000 ppm
Air changes per hour (office)4 – 6
Kitchen hood capture velocity75 – 100 fpm
Duct leakage (sealed system)under 6%

These are the numbers on every commissioning report we hand over.

Stainless steel commercial kitchen exhaust hood
04 — Commercial kitchen exhaust

Hoods that pass, first time

A hood that moves too much air is as much of a failure as one that moves too little: it pulls conditioned air out of the dining room, slams the front door and drives the heating bill up. We size exhaust and make-up air together, always.

  • Type I and Type II hood supply, fabrication and installation
  • NFPA 96 compliant welded stainless duct and access panels
  • Make-up air units with tempered supply for winter service
  • Capture velocity testing and written inspection documentation
  • Scheduled grease-path inspection under a maintenance agreement
05 — Maintenance agreements

Planned visits beat emergency calls

Two or four visits a year depending on the building. Each visit covers filters, belts, bearings, dampers, controls and a set of airflow readings, with a written report emailed within 48 hours.

  • Priority scheduling ahead of non-contract calls
  • 10% off parts and any additional labour
  • Photographic record of every visit, kept for five years
  • Annual budget note for anything approaching end of life
Ask about a plan
06 — Testing & air balancing

Numbers, not opinions

We balance systems we installed and systems we didn't. If a building has hot rooms, cold rooms, whistling grilles or doors that won't close, the pressure relationships are usually wrong and measurable.

  • CFM verification at every diffuser and return
  • Room-to-room pressure mapping
  • Fan curve checks and drive adjustments
  • Signed balance report suitable for permit closeout
See example results
Emergency work

Something down right now?

Kitchen hood dead mid-service, exhaust fan seized, smoke in a corridor — call the office line. Outside hours it forwards to the on-call technician.

24-hour callout

Dispatch within four hours for contract clients, same day where we can for everyone else.

Stocked vans

Belts, motors, capacitors, controls and common filter sizes travel with us, so most faults clear on the first visit.

Honest triage

If a repair isn't worth the money we say so, and we'll price the replacement without pressure.

Call 707-465-0980

Need airflow sorted before the next inspection?

Talk to Holly Fitzgerald directly. Most quotes are back within two business days.

Call 707-465-0980 Request a quote